Created: 05-09-21
Last Login: 05-09-21
Optical Network PON Power Meter
T-PO3213
Description
T-PO3213 Series Optical Network PON Power Meter target at the FTTx application and maintenance. This optical network PON power meter is able to test and estimate the signals of voice simultaneously, data and video. It is an essential and ideal tool for the construction and maintenance of BPON/EPON/GPON projects.
1. It can experiment at Voice, data and video signal synchronous measurement.
2. Providing simultaneous measurement for all three wavelengths on the fiber (1490nm, 1550nm, 1310nm)
3. Used in Burst mode measurement of 1310nm upstream.
4. Use the software connect with PC, setting the threshold, data transfer, and calibration the ave length.
5. USB communication port enables data transfer to PC. 1000pcs measurement results can be saved in T-PO3213 optical network PON power meter or PC for data review.
6. With optical power meter module,include 850,1300,1310,1490,1550,1625nm(T-PO3213AP, T-PO3213A without 850nm wavelength); With visual fault locator module(T-PO3213A and T-PO3213AV)
7. Optical power meter and VFL with one port(only T-PO3213A)
8. Offer up to 10 different threshold sets,Three status LEDs represent different optical signal conditions of Pass, Warn and Fail respectively.
9. 10 minutes Auto-off function can be activated or deactivated
10. Different models corresponding to different functions, according to own use to choose.
PON module
ModelT-PO3213T-PO3213AT-PO3213AVT-PO3213AP
1310 upstream measurement
Pass Zone(nm)1260nm锝?360nm
MeasurementRange(dBm)-40dBm锝?10dBm
Output power(max)15dBm
Isolation@1490/1550(dB)>40dB
Burst mode measurement error40dB
1550 downstream measurement
Pass Zone(nm)1535nm锝?570nm
MeasurementRange(dBm)-40dBm锝?10dBm
Output power(max)25dBm
Isolation@锛?310/1490nm锛?/p>>40dB
Measurement Accuracy
Connatural uncertainty(dB)卤0.5dB
Linearity(dB)卤0.1dB
Passing through insertion Loss(dB)
Storage temperature(鈩?-25鈩冿綖70鈩?/p>
Weight(kg)423g425g424g424g
Note: The operation time of the battery are all for the instrument that do not turn on backlight, if the backlight turn on the operation time will be shorted.
Normal Optical Power Meter Module
ModelT-PO3213鈶?/strong>T-PO3213AT-PO3213AP
Measurement Accuracy
Connatural uncertainty(dB)None卤0.5dB
Linearity(dB)卤0.1dB
Measurement Range(dBm)-70dBm锝?6dBm
General Information
Measurement UnitNonedB/dBm
Resolution (dB)0.01dB
Calibration Wavelength(nm)1300/1310/ 1490/1550/1625850/1300/1310/ 1490/1550/1625
Detector TypenGaAs
Optical ConnectorFC/SC/ST Interchangeable/2.5 universal adapter
鈶? T-PO3213 do not have the OPM module
VFL Module
ModelT-PO3213鈶?/p>T-PO3213AT-PO3213AV
Output powerNone>0.5mW
Wavelength650nm
Optical ConnectorFC/SC/ST Interchangeable/2.5mm universal adapter
Fiber TypeSM/MM
鈶?T-PO3213 without VFL module.Pon Power Meter Made in China
website:http://www.njskycom.com/fiber-optic-equipment/pon-power-meter/
Created: 05-09-21
Last Login: 05-09-21
© Classifieds @ Boreal 2025